What happened?

Today arround noon my battery was nearly fully charged and my Victron was in float mode. Once my Victron MPPT Tracker got in the State "Voltage or Current limit", The power of the MPPT dropped down to ~20W and my Inverter power was also set to this Limit.
Eventhoug there was enough power on the panels available my Inverter produced during the sunny time nearly nothing

Image

To Reproduce Bug

Get Your Victron MPPT in the MPPT state: "Voltage or Current limit" with the following settings:

Image

Then wait till the Victron MPPT regulates down. The Inverter will follow

Expected Behavior

When full Battery pass through is enabled and the MPPT state is "Voltage or Current limit", the invert power should be increased until the max setting of the inverter is reached or the state "MPP Tracker active" is reached

Install Method

Pre-Compiled binary from GitHub releases

What git-hash/version of OpenDTU-OnBattery?

2024.11.20

What firmware variant (PIO Environment)?

generic_esp32s3_usb

Relevant log/trace output

Anything else?

I just realized there was a new release. But this issue is not covered there.

Please confirm the following

  • I believe this issue is a bug that affects all users of OpenDTU-OnBattery, not something specific to my installation.
  • I have already searched for relevant existing issues and discussions before opening this report.
  • I have updated the title field above with a concise description.